Multipair Individually Shielded Data Cables With Overall Screen

Multipair individually shielded data cables with overall screen have individually shielded pairs laid up in aluminum/polyester tape. The cables incorporate a tinned copper drain wire under and in contact with the screen.

Uses: RS 232, RS 422 and RS 485 data transmission and instrumentation applications.

Conductor: Tinned annealed high conductivity copper wire to BS 6360.

Insulation: PVC/PE/PP/XLPE/LSF/LSOH

Individual & Overall Screen: Aluminium/Polyester Tape or Copper Braiding

Shealth: PVC/LSF/LSOH

Product Name/Code: 9855

Electrical Performance

Application:

Max. inner Conductor Resistance (Ω/Km)

54.8

Multi-Conductor-Audio, Control, & Instrumentation Cables

Voltage Rating(V)

150

Construction

Nominal Impedance ( Ω )

100

2Pairs

Stranded Tinned Copper

Nominal Velocity ratio (%)

66%

AWG

22

Capacitance (pF/m) C1

51

Construction (mm)

Solid

Capacitance (pF/m) C2

90

Conductor Diameter (mm)

0.64

 

 

Insulation

PVC/PE/PP/XLPE/LSF/LSOH

 

 

Thickness

0.60

 

 

Insulation Diameter(mm)

1.24

 

 

Insulation Color

Red&Blue, Black&Yellow

 

 

Individual Screen

Aluminum Foil-Polyester Tape

 

 

Coverage

100%

 

 

 

 

Overall Screen

Tinned Copper Braiding

 

 

Coverage

58%

 

 

Construction

Multi pair individually shielded with overall screen laid up in tinned copper braid

 

 

Sheath

PVC/LSF/LSOH

 

 

Thickness(mm)

0.6

 

 

Diameter(mm)

6.9

 

 

Core Identification/Color Code

According to customer request

 

 

Bending Radius

6xOverall Diameter

 

 

Operating Temperature( ℃ )

-20/60

 

 

   
   