                               Marine Cable | 
                             
                            | 
                           
                        
                          
                            
                            
                               | 
                             
                            
                              
                                
                                
                                  Applications : 
                                    
                                      - These steel armoured optical fibre cables are flame retardant, low smoke, halogen free and fire resistant, used for communication and emergency systems that need to be operational during fire.                                     
 
                                     
                                    Construction : 
                                    
                                      - Fibre Element : Loose tube core design. 
 
                                      - Central Strength Element : Steel wire or fibre reinforced plastic (FRP). 
 
                                      - Bedding : Halogen free and flame retardant thermoplastic compound. 
 
                                      - Armour : Galvanized steel wire braid. 
 
                                      - Outer Sheath1 : Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1. 
 
                                      - Outer Sheath2 : Mud resistant and halogen-free thermoplastic compound. 
 
                                       
                                    Standards :  
                                    
                                      - 
                                        
                                                
                                                  IEC 60794  | 
                                                  IEC 60811-2-1  | 
                                                 
                                                
                                                  IIEC 60331-25  | 
                                                  IEC 60332-3-24  | 
                                                 
                                                
                                                  IEC 60332-3-22  | 
                                                  IEC 60754-1,2  | 
                                                 
                                                
                                                  IEC 61034-1,2  | 
                                                  NEK 606:2004  | 
                                                 
                                                                                 
                                       
                                                                         Mechanical and Thermal Properties : 
                                    
                                      - Bending Radius : 20×OD (during installation); 10×OD (fixed installed). 
 
                                      - Temperature Range : -40℃ ~ +70℃. 
 
                                                                          | 
                                 
                                | 
                             
                            | 
                           
                        | 
                   | 
                 
                    | 
           
          
            |   | 
              | 
           
          |