Applications : 
                                    These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.  
                                                                        Standards : 
                                    IEC 60092-353    IEC 60092-351    IEC 60092-359   IEC 60332-1    IEC 60332-3-22 
                                      IEC 60754-1,2     IEC 61034-1,2     NEK 606:2004 
                                    Construction : 
                                    Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.  
                                      Conductor Screen : Semi conducting material.  
                                      Insulation : Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).  
                                      Insulation Screen : Semi conducting material and tinned copper wire braid.  
                                      Bedding : Halogen free compound.  
                                      Armour : Tinned copper wire braid.  
                                      Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10),coloured red.  
                                     
                                                                          Mechanical and Thermal Properties : 
                                    Bending Radius :15×OD (during installation); 9×OD (fixed installed).  
                                      TemperatureRange : -20℃ ~ +90℃. 
                                     |