                    Application: 
                  This cable is used for interconnecting between frames of PCM equipments 
                  with 120W characteristic impedance. 
                   Conductor: 
                  Annealed bare copper or tinned copper 
                   Insulation: 
                  Foamed PE / HDPE 
                   Shielded: 
                  Two wires are twisted to form a pair then shielded with a layer of Al-Mylar 
                  foil. A piece of tinned copper wire is added along with the pair as drain wire.  
                   Assembly: 
                  Suitable number of pairs are assembled to form a cable core. 
                   Overall shield: 
                  a. Layer of Al-Mylar foil with a drain wire. 
                   Sheath: 
                  PVC (polyvinyl Chloride)or LSNHFRPE.( ow-moke Non-Halogen Flame Retardant Polyethylene).   
                   Structur 
                  
                    
                      Conducyor   | 
                      Pair   | 
                      Insulation   | 
                      Cable core   | 
                      Sheath   | 
                      Overall   | 
                      Standard   | 
                     
                    
                      Diameter(mm)   | 
                      (P)   | 
                      Diameter(mm)   | 
                      Diameter(mm)   | 
                      Thickness(mm)   | 
                      Diameter(mm)   | 
                      Length(M)   | 
                     
                    
                       0.5   | 
                      1   | 
                       1.3   | 
                      3.5   | 
                      0.6   | 
                      5.0   | 
                      200   | 
                     
                    
                      2   | 
                      6.0   | 
                      0.6   | 
                      7.5   | 
                      200   | 
                     
                    
                      4   | 
                      7.0   | 
                      0.6   | 
                      8.5   | 
                      500   | 
                     
                    
                      8   | 
                      10.0   | 
                      0.6   | 
                      11.5   | 
                      500   | 
                     
                    
                      10   | 
                      10.0   | 
                      0.6   | 
                      11.5   | 
                      500   | 
                     
                    
                      16   | 
                      13.5   | 
                      0.8   | 
                      16.0   | 
                      500   | 
                     
                    
                      22   | 
                      16.0   | 
                      1.0   | 
                      18.3   | 
                      500   | 
                     
                    
                      25   | 
                      16.0   | 
                      1.0   | 
                      18.5   | 
                      500   | 
                     
                    
                      32   | 
                      19.0   | 
                      1.0   | 
                      21.5   | 
                      500   | 
                     
                    
                      40   | 
                      21.0   | 
                      1.5   | 
                      24.5   | 
                      500  | 
                     
                                     
                   Characteristics: 
                  
                    
                      Items   | 
                      Specification   | 
                     
                    
                      Conductor Resistance (20℃)   | 
                      Max.100.2W / Km   | 
                     
                    
                      Conductor Resistance unbalance(20℃)   | 
                      Max.5 ﹪   | 
                     
                    
                      Insulation Resistance (20℃,DC 500V / 1min.)   | 
                      Min.5000M - Km   | 
                     
                    
                      Dielectric strength   | 
                      DC 1000V / 1min. Between Conductors   | 
                     
                    
                      DC 1500V / 1min. Between Conductors and shield   | 
                     
                    
                      Static Capacitance (1KHz)   | 
                      Max.50 nf / Km   | 
                     
                    
                      Attenuation. (1024 KHz)   | 
                      Max.34 dB / Km   | 
                     
                    
                      Characteristic Impedance (1024 KHz)   | 
                      120 ± 10W   | 
                     
                    
                      Near-end cross talk (1024 KHz)   | 
                      Min.70 dB / 500M  | 
                     
                                        |