K209B LSZH Armoured Optical Fiber Cables
Application
The cables are designed for long distance telecommunication and using optical fibres in urban railways infrastructure. These low smoke halogen-free cables are laid on hooks, pulled through ducts or cable trays.
Standards
● RATP K209B or RATP K209A
Construction
Compact Tube
6 or 12 singlemode optical fibres G652 or multimode fi bers assembled under thermoplastic “peelable” skin. Tube diameter: 1mm.
Filling
Water-swelling yarns.
Tube
Thermoplastic.
Peripheral Strength Member
Water-swelling glass yarns.
Armour
Corrugated steel tape armour 25/100.
Sheath
LSZH.
Optional
K209A Type: For K209A type, the cables have loose tubes with 6-12 fi bers, steel wire strand as central strength
member, glass yarn reinforced, incorporating a corrugated steel tape armour and an outer UV stabilized LSZH jacket.
Electrical Characteristics at 20℃
Optical & Geometrical Properties for Single Mode Fibers
Maximum Attenuation |
|
G652 |
@1310nm |
dB/km |
0.35 |
@1550nm |
dB/km |
0.22 |
Maximum Chromatic Dispersion |
|
|
Between 1260 and 1360nm |
ps/(nm/km) |
3.5 |
Between 1530 and 1565nm |
ps/(nm/km) |
19 |
Zero Dispersion Wavelength |
nm |
1310±11 |
Zero Dispersion Slope |
ps/(nm2.km) |
0.09 |
Numerical Aperture |
|
0.14 |
Point discontinuity |
dB |
0.1 |
PMD (individual fi ber) |
ps/km |
0.2 |
Maximum Cutoff Wavelength |
nm |
1260 |
Cladding Diameter |
um |
125±1 |
Core/Cladding Concentricity Error |
um |
≤0.5 |
Cladding Non Circularity |
% |
≤1 |
Coating Non Circularity |
% |
≤6 |
Proof Test Level |
Kpsi (GN/m2) |
100 (0.7) |
Crush Resistance |
N/cm |
300 |
Maximum Laying Tension |
N |
3000 |
Optical & Geometrical Properties for Multimode Fibers
|
|
50/125 |
62.5/125 |
Maximum Attenuation |
|
|
|
@850nm |
dB/km |
≤2.5 |
≤3.0 |
@1300nm |
dB/km |
≤0.7 |
≤0.8 |
Maximum Chromatic Dispersion |
|
|
|
@850nm |
MHz*km |
≥500 |
≥200 |
@1300nm |
MHz*km |
≥800 |
≥500 |
Zero Dispersion Wavelength |
nm |
1310 |
1310 |
Numerical Aperture |
- |
0.20±0.015 |
0.275±0.015 |
Core Diameter |
um |
50±3 |
62.5±3 |
Cladding Diameter |
um |
125±2 |
125±2 |
Core/Cladding Concentricity Error(Offset) |
um |
≤1.5 |
≤1.5 |
Coating-Clad Concentricity Error(Offset) |
um |
≤8 |
≤8 |
Core Non-Circularity |
% |
≤6 |
≤6 |
Cladding Non-Circularity |
% |
≤2 1 |
≤2 1 |
Coating Diameter |
um |
245±10 |
245±10 |
Proof-Test Level |
Kpsi (GN/m2) |
100 (0.7) |
100 (0.7) |
Mechanical and Thermal Properties
Minimum Bending Radius:20×OD
Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation) |