K26 LSZH 50/75Ω Coaxial Cables
Application
The 50Ω cables are HF transmission coaxial cables for GSM antennas, and the 75Ω cables are HF transmission coaxial cables for cameras (type KX6), and video surveillance (type 11 RTC). The Halogen-free cables are suitable for laid on hooks, and pulled through walls or through technical ducts.
Standards
● RATP K26
● Fire Performance: NF C 32070.2.2
Construction
Inner Conductors
50Ω cables:
Flexible Type (F)- solid copper coated aluminium (for 1/4″ , 3/8″ &1/2″ F conductor); red copper tube (for
7/8″ and 1'1/4 F conductor); corrugated red copper tube (for 1'5/8 F conductor).
Super Flexible Type (SF) - solid copper coated aluminium (for 3/8″ & 1/2″ SFconductor); helical corrugated
copper tube (for 7/8” SF conductor); copper wire (for 1/4″ SFconductor).
Extra Flexible (XF) – copper wire (for 1/4" XF conductor); solid copper coated aluminium (for 3/8" XF
conductor).
75Ω cables: solid red copper (for type 11 RTC) or red copper tube (for type KX6).
Dielectric
Cellular PE or natural PE (only for KX6 type).
Outer Conductor
50Ω cables: corrugated copper tube.
75Ω cables: copper braid.
Outer sheath
LSZH.
Electrical Characteristics at 20℃
50Ω Cables
Type of Cable |
inch |
1/4"F |
3/8"F |
1/2"F |
7/8"F |
1'1/4F |
1'5/8F |
Impedance |
Ω |
50 |
50 |
50 |
50 |
50 |
50 |
Attenuation |
|
|
|
|
|
|
|
@10MHz |
dB/100m |
1.25 |
1.46 |
0.65 |
0.34 |
0.25 |
0.2 |
@150MHz |
dB/100m |
4.99 |
4.22 |
2.61 |
1.45 |
1.02 |
0.85 |
@200MHz |
dB/100m |
5.8 |
4.90 |
3.04 |
1.69 |
1.19 |
1.00 |
@450MHz |
dB/100m |
8.8 |
7.51 |
4.66 |
2.61 |
1.86 |
1.57 |
@900MHz |
dB/100m |
12.8 |
11.1 |
6.78 |
3.81 |
2.75 |
2.34 |
@1000MHz |
dB/100m |
13.5 |
11.6 |
7.18 |
4.04 |
2.93 |
2.49 |
@1500MHz |
dB/100m |
17.0 |
14.4 |
8.99 |
5.08 |
3.72 |
3.17 |
@1500MHz |
dB/100m |
18.3 |
15.5 |
9.64 |
5.45 |
4.01 |
3.42 |
Average Power Rating |
|
|
|
|
|
|
|
@10MHz |
KW |
5.79 |
7.23 |
13 |
28.0 |
41 |
57 |
@150MHz |
KW |
1.45 |
1.81 |
3.2 |
7.0 |
11 |
13 |
@200MHz |
KW |
1.25 |
1.56 |
2.75 |
6.0 |
9.0 |
11 |
@450MHz |
KW |
0.818 |
1.02 |
1.8 |
3.88 |
5.5 |
6.9 |
@900MHz |
KW |
0.566 |
0.70 |
1.25 |
2.65 |
3.83 |
4.49 |
@1000MHz |
KW |
0.533 |
0.663 |
1.18 |
2.50 |
3.60 |
4.20 |
@1500MHz |
KW |
0.426 |
0.53 |
0.947 |
1.99 |
2.82 |
3.22 |
@1700MHz |
KW |
0.398 |
0.494 |
0.884 |
1.85 |
2.61 |
2.96 |
Velocity of Propagation |
% |
85 |
88 |
88 |
88 |
88 |
88 |
Type of Cable
|
inch |
1/4"SF |
3/8"SF |
1/2"SF |
7/8"SF |
1/4"XF |
3/8"XF |
Impedance |
Ω |
50 |
50 |
50 |
50 |
50 |
50 |
Attenuation |
|
|
|
|
|
|
|
@10MHz |
dB/100m |
1.71 |
1.3 |
0.83 |
0.39 |
2.31 |
1.098 |
@150MHz |
dB/100m |
6.89 |
4.89 |
3.87 |
1.59 |
7.44 |
4.38 |
@200MHz |
dB/100m |
8.01 |
5.59 |
4.53 |
1.85 |
8.54 |
5.098 |
@450MHz |
dB/100m |
12.31 |
8.49 |
7.09 |
2.85 |
14.3 |
7.83 |
@900MHz |
dB/100m |
17.92 |
12.66 |
10.45 |
4.15 |
20.5 |
11.4 |
@1000MHz |
dB/100m |
18.98 |
13.5 |
11.09 |
4.4 |
21.83 |
12.1 |
@1500MHz |
dB/100m |
23.78 |
17.43 |
13.98 |
5.52 |
27.13 |
15.1 |
@1700MHz |
dB/100m |
25.51 |
18.91 |
15.03 |
5.92 |
29.5 |
16.2 |
Average Power Rating |
|
|
|
|
|
|
|
@10MHz |
KW |
2.8 |
6.0 |
8.4 |
21.5 |
3.8 |
7.02 |
@150MHz |
KW |
0.7 |
1.52 |
2.1 |
5.4 |
0.9 |
1.76 |
@200MHz |
KW |
0.6 |
1.31 |
1.81 |
4.6 |
0.8 |
1.51 |
@450MHz |
KW |
0.39 |
0.86 |
1.18 |
3.0 |
0.51 |
0.99 |
@900MHz |
KW |
0.272 |
0.593 |
0.815 |
2.07 |
0.37 |
0.68 |
@1000MHz |
KW |
0.257 |
0.56 |
0.77 |
1.95 |
0.34 |
0.64 |
@1500MHz |
KW |
0.206 |
0.449 |
0.616 |
1.55 |
0.26 |
0.51 |
@1700MHz |
KW |
0.192 |
0.42 |
0.575 |
1.45 |
0.24 |
0.48 |
Velocity of Propagation |
% |
83 |
81 |
82 |
88 |
84 |
85 |
75Ω Cables
Type of Cable |
inch |
11 RTC |
KX6 |
Impedance |
Ω |
75 |
75 |
@50MHz |
dB/100m |
2.5 |
8.13 |
@100MHz |
dB/100m |
3.6 |
11.73 |
@150MHz |
dB/100m |
4.6 |
14.73 |
@200MHz |
dB/100m |
5.4 |
16.92 |
@500MHz |
dB/100m |
8.5 |
27.0 |
@800MHz |
dB/100m |
10.5 |
35.1 |
@1000MHz |
dB/100m |
12.2 |
40.02 |
Velocity of Propagation |
% |
87 |
66 |
Mechanical and Thermal Properties
Minimum Bending Radius: 7.5×OD
Temperature Range:
50Ω cables: -40℃ to +85℃ (during operation); -20℃ to +60℃ (during installation);
75Ω cables: -20℃ to +85℃ (during operation); -10℃ to +60℃ (during installation). |