ATL Your Reliable Supplier of Network Cable, Coaxial Cable & Fiber Optic Cable...
   
  Production Facilities
 
 
Hot Product
 
RJ45-RJ45 Patch Cord

RJ45-RJ45 Patch Cord complying with Component Compliancy of TIA/EIA 568, ISO/IEC 11801. (UTP/FTP/STP/SFTP Cat.5e/Cat.6 RJ45-RJ45 Patch Cord)

More...
 
Fiber Optic Patch Cord Series
Fiber Optic Patch Cord Series. (ST/SC/FC/SMA/MU/FDDI/
ESCON/MTRJ/LC/D4/E2000
Connector Type)
More...
   
 
Railway Cables
 

SW-CLT Switching Centre Cables

SW-CLT Switching Centre Cables

Application

The cables are used as block cables for railway. The cables are suitable for connection between local switching centre and the trackside and signalling equipments.

Standards

● CFF: I-EB-SK 3001.82.1000

Construction

Conductors
Class 1 solid copper, 1.0/1.5/2.2mm nominal diameter.

Insulation
Solid polyethylene.

Cabling Element
Four conductors are twisted together to form a quad.

Inner Sheath
PE sheath.

Armour
Double galvanized steel tapes of 0.15mm.

Outer Sheath
PE/LSZH sheath.

Optional

Unarmoured Cable: The cables offered without galvanized steel tapes (SW).
Traction Armoured Cable: The cables offered with galvanized steel fl at wire armour with or without protection sheath (SW-F/FT).
Halogenfree Sheathed Cable: The cables offered with LSZH sheath according to IEC 60332-3C (SW-CLN/FN).

Electrical Characteristics at 20℃

Nominal Conductor Diameter
mm
1.0
1.5
2.2
Maximum Conductor Resistance (DC)
Ω/km
47.0
20.9
10.0
Minimum Insulation Resistance @500 V DC (3mins)
MΩ.km
10000
10000
10000
Maximum Mutual Capacitance @800Hz
nF/km
42
52
60
Maximum Capacitance Unbalance
In quad
pF/km
400
400
400
Between quads
pF/km
400
400
400
Real-ground
pF/km
650
650
650
Operating Voltage AC/DC
V
500/800

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD
Temperature Range: -30℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

 

 
   
   
  Copyright © 1995, ATL Technology Ltd. All rights are reserved.