MW-1SU/FRL-MW-3SU
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control,l auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)
MW-1SU 0.6/1 kV
NOMINALCROSS-SECTIONAL AREA
(a) |
CONDUCTOR DIAMETER (a) |
MIN. MEAN THICKNESS OF INSULATION |
OVERALL DIAMETER MIN.(mm) |
OVERALL DIAMETER MAX.(mm) |
WEIGHT |
CONDUCTOR RESISTANCE AT +20°C |
INSULATION RESISTANCE AT +20°C |
INSULATION RESISTANCE AT +90°C |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
Kg/km |
Ω/km |
MΩ·km |
MΩ·km |
1.0 |
1.25 |
0.6 |
2.4 |
2.8 |
10 |
20 |
11.4 |
0.114 |
1.5 |
1.5 |
0.7 |
2.8 |
3.3 |
20 |
13.7 |
11.0 |
0.110 |
2.5 |
1.95 |
0.7 |
3.2 |
3.8 |
30 |
8.21 |
9.1 |
0.091 |
4 |
2.5 |
0.7 |
3.8 |
4.4 |
50 |
5.09 |
7.5 |
0.075 |
6 |
3.0 |
0.7 |
4.2 |
5.0 |
60 |
3.39 |
6.5 |
0.065 |
10 |
3.9 |
0.7 |
5.1 |
5.9 |
110 |
1.95 |
5.2 |
0.052 |
16 |
5.0 |
0.7 |
6.1 |
7.2 |
160 |
1.24 |
4.2 |
0.042 |
25 |
6.4 |
0.9 |
7.8 |
9.1 |
240 |
0.795 |
4.1 |
0.041 |
35 |
7.7 |
0.9 |
9.0 |
10.6 |
330 |
0.565 |
3.5 |
0.035 |
50 |
9.2 |
1.0 |
10.6 |
12.4 |
460 |
0.393 |
3.3 |
0.033 |
70 |
11.0 |
1.1 |
12.5 |
14.6 |
660 |
0.277 |
3.0 |
0.030 |
95 |
12.5 |
1.1 |
13.9 |
16.3 |
860 |
0.210 |
2.7 |
0.027 |
120 |
14.2 |
1.2 |
15.7 |
18.4 |
1080 |
0.164 |
2.7 |
0.027 |
150 |
15.8 |
1.4 |
17.6 |
20.6 |
1370 |
0.132 |
2.7 |
0.027 |
185 |
17.5 |
1.6 |
19.6 |
22.9 |
1690 |
0.108 |
2.6 |
0.026 |
240 |
20.1 |
1.7 |
22.2 |
26.0 |
2230 |
0.0817 |
2.6 |
0.026 |
300 |
22.5 |
1.8 |
24.6 |
28.8 |
2780 |
0.0654 |
2.4 |
0.024 |
400 |
25.8 |
2.0 |
28.1 |
32.9 |
3740 |
0.0495 |
2.4 |
0.024 |
MW-3SU 1.8/3 kV
NOMINALCROSS-SECTIONAL AREA
(a) |
CONDUCTOR DIAMETER (a) |
MIN. MEAN THICKNESS OF INSULATION |
OVERALL DIAMETER MIN.(mm) |
OVERALL DIAMETER MAX.(mm) |
WEIGHT |
CONDUCTOR RESISTANCE AT +20°C |
INSULATION RESISTANCE AT +20°C |
INSULATION RESISTANCE AT +90°C |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
Kg/km |
Ω/km |
MΩ·km |
MΩ·km |
1.5 |
1.5 |
2.0 |
5.3 |
6.2 |
50 |
13.7 |
21.0 |
0.210 |
2.5 |
1.95 |
2.0 |
5.7 |
6.7 |
60 |
8.21 |
18.0 |
0.180 |
4 |
2.5 |
2.0 |
6.2 |
7.3 |
80 |
5.09 |
15.5 |
0.155 |
6 |
3.0 |
2.0 |
6.7 |
7.8 |
100 |
3.39 |
13.7 |
0.137 |
10 |
3.9 |
2.0 |
7.5 |
8.8 |
150 |
1.95 |
11.5 |
0.115 |
16 |
5.0 |
2.0 |
8.6 |
10.0 |
220 |
1.24 |
9.5 |
0.095 |
25 |
6.4 |
2.0 |
9.9 |
11.6 |
290 |
0.795 |
7.9 |
0.079 |
35 |
7.7 |
2.0 |
11.1 |
13.0 |
390 |
0.565 |
6.8 |
0.068 |
50 |
9.2 |
2.0 |
12.5 |
14.6 |
530 |
0.393 |
5.9 |
0.059 |
70 |
11.0 |
2.0 |
14.2 |
16.6 |
720 |
0.277 |
5.0 |
0.050 |
95 |
12.5 |
2.2 |
16.0 |
18.7 |
940 |
0.210 |
4.5 |
0.045 |
120 |
14.2 |
2.2 |
17.6 |
20.6 |
1160 |
0.164 |
4.0 |
0.040 |
150 |
15.8 |
2.2 |
19.1 |
22.3 |
1440 |
0.132 |
3.7 |
0.037 |
185 |
17.5 |
2.4 |
20.9 |
24.4 |
1760 |
0.108 |
3.4 |
0.034 |
240 |
20.1 |
2.4 |
23.7 |
27.5 |
2350 |
0.0817 |
3.0 |
0.030 |
300 |
22.5 |
2.4 |
25.6 |
30.1 |
2820 |
0.0654 |
2.7 |
0.027 |
400 |
25.8 |
2.6 |
29.2 |
34.2 |
3730 |
0.0495 |
2.4 |
0.024 |
(a)= For information,indicative only |