MW-3S/MW-6S
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)
Sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
MW-3S 1.8/3 kV
NOMINALCROSS-SECTIONAL AREA
(a) |
CONDUCTOR DIAMETER (a) |
MIN.
MEAN THICKNESS OF INSULATION |
SHEATH NOMINAL THICKNESS MIN. |
OVERALL DIAMETER MIN. |
OVERALL DIAMETER MAX. |
WEIGHT |
COND
UCTOR RESIST
ANCEAT
+20°C |
INSULATION RESISTANCE AT +20°C |
INSULATION RESISTANCE AT +90°C |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/km |
Ω/km |
MΩ·km |
MΩ·km |
1.5 |
1.5 |
1.3 |
0.8 |
5.7 |
6.7 |
60 |
13.7 |
21.8 |
0.218 |
2.5 |
1.95 |
1.3 |
0.8 |
6.0 |
7.0 |
70 |
8.21 |
18.8 |
0.188 |
4 |
2.5 |
1.3 |
0.8 |
6.5 |
7.6 |
90 |
5.09 |
16.2 |
0.162 |
6 |
3.0 |
1.3 |
0.8 |
7.0 |
8.1 |
110 |
3.39 |
14.4 |
0.144 |
10 |
3.9 |
1.5 |
0.8 |
8.2 |
9.6 |
170 |
1.95 |
12.8 |
0.128 |
16 |
5.0 |
1.5 |
0.8 |
9.2 |
10.8 |
240 |
1.24 |
10.7 |
0.107 |
25 |
6.4 |
1.8 |
1.0 |
11.5 |
13.4 |
350 |
0.795 |
10.3 |
0.103 |
35 |
7.7 |
1.8 |
1.0 |
12.7 |
14.9 |
450 |
0.565 |
8.9 |
0.089 |
50 |
9.2 |
1.8 |
1.0 |
14.1 |
16.5 |
590 |
0.393 |
7.8 |
0.078 |
70 |
11.0 |
1.8 |
1.0 |
15.8 |
18.5 |
790 |
0.277 |
6.7 |
0.067 |
95 |
12.5 |
2.2 |
1.0 |
18.0 |
21.0 |
1050 |
0.210 |
6.5 |
0.065 |
120 |
14.2 |
2.2 |
1.0 |
19.6 |
22.9 |
1270 |
0.164 |
6.1 |
0.061 |
150 |
15.8 |
2.2 |
1.2 |
21.4 |
25.1 |
1590 |
0.132 |
5.8 |
0.058 |
185 |
17.5 |
2.4 |
1.2 |
23.4 |
27.4 |
1900 |
0.108 |
5.6 |
0.056 |
240 |
20.1 |
2.4 |
1.2 |
25.9 |
30.3 |
2490 |
0.0817 |
5.0 |
0.050 |
300 |
22.5 |
2.4 |
1.2 |
28.1 |
32.9 |
3010 |
0.0654 |
4.5 |
0.045 |
400 |
25.8 |
2.6 |
1.4 |
32.0 |
37.4 |
3980 |
0.0495 |
4.4 |
0.044 |
MW-6S 3.6/6KV
NOMINALCROSS-SECTIONAL AREA |
CONDUCTOR DIAMETER (a) |
MIN.
MEAN THICKNESS OF INSULATION |
SHEATH NOMINAL THICK
NESS MIN. |
OVERALL DIAMETER MIN. |
OVERALL DIAMETER MAX. |
WEIGHT |
CONDUCTOR RESIST
ANCEAT +20°C |
INSULATION RESISTANCE AT +20°C |
INSULATION RESISTANCE AT +90°C |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/km |
Ω/km |
MΩ·km |
MΩ·km |
2.5 |
1.95 |
2.6 |
0.8 |
8.6 |
10.1 |
120 |
8.21 |
24.6 |
0.246 |
4 |
2.5 |
2.6 |
0.8 |
9.1 |
10.7 |
140 |
5.09 |
21.6 |
0.216 |
6 |
3.0 |
2.6 |
0.8 |
9.6 |
11.2 |
165 |
3.39 |
19.5 |
0.195 |
10 |
3.9 |
2.6 |
0.8 |
10.4 |
12.2 |
220 |
1.95 |
16.7 |
0.167 |
16 |
5.0 |
2.6 |
0.8 |
11.5 |
13.4 |
290 |
1.24 |
14.2 |
0.142 |
25 |
6.4 |
2.9 |
1.0 |
13.7 |
16.1 |
430 |
0.795 |
13.1 |
0.131 |
35 |
7.7 |
2.9 |
1.0 |
14.9 |
17.5 |
540 |
0.565 |
11.6 |
0.116 |
50 |
9.2 |
2.9 |
1.0 |
16.4 |
19.1 |
670 |
0.393 |
10.2 |
0.102 |
70 |
11.0 |
2.9 |
1.0 |
18.0 |
21.1 |
880 |
0.277 |
8.9 |
0.089 |
95 |
12.5 |
2.9 |
1.0 |
19.5 |
22.8 |
1100 |
0.210 |
8.0 |
0.080 |
120 |
14.2 |
2.9 |
1.2 |
21.4 |
25.1 |
1380 |
0.164 |
7.5 |
0.075 |
150 |
15.8 |
2.9 |
1.2 |
22.9 |
26.8 |
1660 |
0.132 |
6.9 |
0.069 |
185 |
17.5 |
3.2 |
1.2 |
25.1 |
29.4 |
2010 |
0.108 |
6.7 |
0.067 |
240 |
20.1 |
3.4 |
1.4 |
28.3 |
33.1 |
2670 |
0.0817 |
6.4 |
0.064 |
300 |
22.5 |
3.4 |
1.4 |
30.6 |
35.8 |
3170 |
0.0654 |
5.9 |
0.059 |
400 |
25.8 |
3.4 |
1.4 |
33.7 |
39.4 |
4150 |
0.0495 |
5.2 |
0.052 |
(a)= For information,indicative only |