SW-1SU/SW-3SU
Application
-Used as power and control cable for protected installations inside and outside of rail and
transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards
and control panels, driver desks etc. Construction Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5 Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 104)
SW-1SU 0.6/1 kV
NOMINAL CROSS-SECTIONAL AREA |
CONDUCTOR DIAMETER (a) |
MIN. MEAN THICKNESS OF INSULATION |
OVERALL DIAMETER |
WEIGHT |
CONDUCTOR RESISTANCE AT 20°C |
INSULATION RESISTANCE AT 20°C |
INSULATION RESISTANCE AT 90°C |
min |
max |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
MΩ·km |
MΩ·km |
1.0 |
1.25 |
0.8 |
2.8 |
3.2 |
18 |
20 |
65 |
0.65 |
1.5 |
1.5 |
0.8 |
3.0 |
3.5 |
20 |
13.7 |
55 |
0.55 |
2.5 |
1.95 |
0.8 |
3.4 |
3.9 |
30 |
8.21 |
50 |
0.5 |
4.0 |
2.5 |
0.8 |
3.9 |
4.6 |
50 |
5.09 |
40 |
0.4 |
6.0 |
3.0 |
0.9 |
4.6 |
5.4 |
70 |
3.39 |
35 |
0.35 |
10 |
3.9 |
1.1 |
5.8 |
6.8 |
130 |
1.95 |
30 |
0.3 |
16 |
5.0 |
1.1 |
7.2 |
8.5 |
170 |
1.24 |
30 |
0.3 |
25 |
6.4 |
1.3 |
8.6 |
10 |
260 |
0.795 |
30 |
0.3 |
35 |
7.7 |
1.3 |
10.2 |
11.5 |
350 |
0.565 |
25 |
0.25 |
50 |
9.2 |
1.5 |
11.6 |
13.5 |
500 |
0.393 |
25 |
0.25 |
70 |
11.0 |
1.5 |
13.3 |
15.5 |
690 |
0.277 |
20 |
0.2 |
95 |
12.5 |
1.6 |
14.9 |
17.4 |
910 |
0.210 |
20 |
0.2 |
120 |
14.2 |
1.6 |
16.5 |
19.3 |
1120 |
0.164 |
20 |
0.2 |
150 |
15.8 |
1.9 |
18.5 |
21.7 |
1430 |
0.132 |
15 |
0.15 |
185 |
17.5 |
1.9 |
20.1 |
23.6 |
1720 |
0.108 |
15 |
0.15 |
240 |
20.1 |
2.1 |
22.9 |
26.8 |
2290 |
0.0817 |
15 |
0.15 |
300 |
22.5 |
2.2 |
25.4 |
29.7 |
2810 |
0.0654 |
10 |
0.1 |
400 |
25.8 |
2.3 |
28.7 |
33.6 |
2690 |
0.0495 |
10 |
0.1 |
(a) = for information, indicative only SW-3SU 1.8/3 kV
NOMINAL CROSS-SECTIONAL AREA |
CONDUCTOR DIAMETER (a) |
MIN. MEAN THICKNESS OF INSULATION |
OVERALL DIAMETER |
WEIGHT |
RESISTANCE OF CONDUCTOR AT 20°C |
INSULATION RESISTANCE AT 20°C |
INSULATION RESISTANCE AT90°C |
min |
max |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
MΩ·km |
MΩ·km |
1.5 |
1.5 |
2.5 |
6.2 |
7.3 |
70 |
13.7 |
120 |
1.2 |
2.5 |
1.95 |
2.5 |
6.6 |
7.8 |
90 |
8.21 |
100 |
1.0 |
4.0 |
2.5 |
2.5 |
7.1 |
8.4 |
110 |
5.09 |
90 |
0.9 |
6.0 |
3.0 |
2.5 |
7.6 |
8.9 |
130 |
3.39 |
80 |
0.8 |
10 |
3.9 |
2.5 |
8.4 |
9.9 |
190 |
1.95 |
65 |
0.65 |
16 |
5.0 |
2.5 |
9.5 |
11.1 |
250 |
1.24 |
50 |
0.55 |
25 |
6.4 |
2.5 |
10.8 |
12.7 |
330 |
0.795 |
45 |
0.45 |
35 |
7.7 |
2.5 |
12.0 |
14.1 |
430 |
0.565 |
40 |
0.4 |
50 |
9.2 |
2.5 |
13.4 |
15.7 |
570 |
0.393 |
35 |
0.35 |
70 |
11.0 |
2.5 |
15.1 |
17.7 |
760 |
0.277 |
30 |
0.3 |
95 |
12.5 |
2.7 |
16.9 |
19.8 |
980 |
0.210 |
30 |
0.3 |
120 |
14.2 |
2.7 |
18.5 |
21.7 |
1210 |
0.164 |
25 |
0.25 |
150 |
15.8 |
2.7 |
20.0 |
23.4 |
1500 |
0.132 |
20 |
0.2 |
185 |
17.5 |
2.7 |
21.6 |
25.3 |
1800 |
0.108 |
20 |
0.2 |
240 |
20.1 |
2.7 |
24.1 |
28.2 |
2360 |
0.0817 |
20 |
0.2 |
300 |
22.5 |
2.7 |
26.3 |
30.8 |
2840 |
0.0654 |
15 |
0.15 |
400 |
25.8 |
2.9 |
29.8 |
34.9 |
3800 |
0.0495 |
15 |
0.15 |
a) = for information, indicative only
|