SW-3S/SW-6S
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 104)
Sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
SW-3S 1.8/3 kV
NOMINAL CROSS-SECTIONAL AREA |
CONDUCTOR DIAMETER (a) |
MIN. MEAN THICKNESS OF INSULATION |
MIN. MEAN THICKNESS OF SHEATH |
OVERALL DIAMETER |
WEIGHT |
CONDUCTOR RESISTANCE AT |
INSULATION RESISTANCE AT |
INSULATION RESISTANCE AT |
|
min |
max |
|
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
MΩ·km |
MΩ·km |
1.5 |
1.5 |
1.3 |
1.4 |
6.7 |
7.8 |
80 |
13.7 |
960 |
9.6 |
2.5 |
1.95 |
1.3 |
1.4 |
7.1 |
8.3 |
100 |
8.21 |
850 |
8.5 |
4.0 |
2.5 |
1.3 |
1.4 |
7.6 |
8.9 |
120 |
5.09 |
750 |
7.5 |
6.0 |
3.0 |
1.3 |
1.4 |
8.1 |
9.5 |
140 |
3.39 |
670 |
6.7 |
10 |
3.9 |
2.2 |
1.4 |
10.6 |
12.4 |
250 |
1.95 |
550 |
5.5 |
16 |
5.0 |
2.2 |
1.4 |
11.7 |
13.6 |
310 |
1.24 |
450 |
4.5 |
25 |
6.4 |
2.2 |
1.4 |
13.0 |
15.2 |
410 |
0.795 |
390 |
3.9 |
35 |
7.7 |
2.2 |
1.4 |
14.2 |
16.6 |
520 |
0.565 |
350 |
3.5 |
50 |
9.2 |
2.2 |
1.4 |
15.6 |
18.3 |
660 |
0.393 |
300 |
3.0 |
70 |
11.0 |
2.2 |
1.5 |
17.5 |
20.5 |
880 |
0.277 |
260 |
2.6 |
95 |
12.5 |
2.4 |
1.6 |
19.6 |
22.3 |
1130 |
0.210 |
250 |
2.5 |
120 |
14.2 |
2.4 |
1.6 |
21.1 |
24.6 |
1370 |
0.164 |
220 |
2.2 |
150 |
15.8 |
2.4 |
1.7 |
22.7 |
26.6 |
1690 |
0.132 |
210 |
2.1 |
185 |
17.5 |
2.4 |
1.7 |
24.0 |
28.1 |
2000 |
0.108 |
200 |
2.0 |
240 |
20.1 |
2.4 |
1.8 |
27.0 |
31.6 |
2620 |
0.0817 |
180 |
1.8 |
300 |
22.5 |
2.4 |
1.9 |
29.4 |
34.4 |
3140 |
0.0654 |
170 |
1.7 |
400 |
25.8 |
2.6 |
2.0 |
32.7 |
38.3 |
4140 |
0.0495 |
150 |
1.5 |
SW-6S 3/6 kV
NO
MINAL CROSS-SECT
IONAL AREA |
COND
UCTOR DIAMETER (a) |
MIN.
MEAN THICKNESS OF INSUL
ATION |
MIN.
MEAN THICK
NESS
OF
SHEATH |
OVERALL DIAM
ETER |
WEIGHT |
CONDU
CTOR RESIST
ANCEAT
20°C |
INSULATION RESISTANCE AT 20°C |
INSULATION RESISTANCE AT 90°C |
min |
max |
max |
min |
min |
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
MΩ·km |
MΩ·km |
2.5 |
1.95 |
3.0 |
1.4 |
10.5 |
12.3 |
170 |
8.21 |
1300 |
13 |
4.0 |
2.5 |
3.0 |
1.4 |
11.0 |
12.9 |
190 |
5.09 |
1150 |
11.5 |
6.0 |
3.0 |
3.0 |
1.4 |
11.5 |
13.4 |
230 |
3.39 |
1050 |
10.5 |
10 |
3.9 |
3.0 |
1.4 |
12.3 |
14.4 |
300 |
1.95 |
850 |
8.5 |
16 |
5.0 |
3.0 |
1.4 |
13.3 |
15.6 |
360 |
1.24 |
710 |
7.1 |
25 |
6.4 |
3.0 |
1.4 |
14.7 |
17.2 |
450 |
0.795 |
630 |
6.3 |
35 |
7.7 |
3.0 |
1.4 |
15.9 |
18.6 |
560 |
0.565 |
550 |
5.5 |
50 |
9.2 |
3.0 |
1.5 |
17.5 |
20.5 |
720 |
0.393 |
500 |
5.0 |
70 |
11.0 |
3.0 |
1.5 |
19.2 |
22.4 |
930 |
0.277 |
430 |
4.3 |
95 |
12.5 |
3.0 |
1.6 |
20.8 |
24.3 |
1160 |
0.210 |
400 |
4.0 |
120 |
14.2 |
3.1 |
1.7 |
22.7 |
26.6 |
1430 |
0.164 |
360 |
3.6 |
150 |
15.8 |
3.1 |
1.7 |
24.2 |
28.4 |
1740 |
0.132 |
340 |
3.4 |
185 |
17.5 |
3.2 |
1.8 |
26.2 |
30.7 |
2080 |
0.108 |
330 |
3.3 |
240 |
20.1 |
3.4 |
1.9 |
29.2 |
34.2 |
2730 |
0.0817 |
300 |
3.0 |
300 |
22.5 |
3.4 |
1.9 |
31.5 |
36.9 |
3230 |
0.0654 |
250 |
2.5 |
400 |
25.8 |
3.4 |
2.0 |
34.8 |
40.7 |
4210 |
0.0495 |
230 |
2.3 |
(a)= for information, indicative only
|