ATL Your Reliable Supplier of Network Cable, Coaxial Cable & Fiber Optic Cable...
   
  Production Facilities
 
 
Hot Product
 
RJ45-RJ45 Patch Cord

RJ45-RJ45 Patch Cord complying with Component Compliancy of TIA/EIA 568, ISO/IEC 11801. (UTP/FTP/STP/SFTP Cat.5e/Cat.6 RJ45-RJ45 Patch Cord)

More...
 
Fiber Optic Patch Cord Series
Fiber Optic Patch Cord Series. (ST/SC/FC/SMA/MU/FDDI/
ESCON/MTRJ/LC/D4/E2000
Connector Type)
More...
   
 
Special Cables
Product Name/Code :truck- M,N

Temperature range:

  • TRUCK M: -40°C to +85°C
  • TRUCK N: -40°C to +85°C

Test voltage:

  • TRUCK M: 2000 V
  • TRUCK N: 3000 V

Minimum bending radius:

  • TRUCK M: fixed installation 5x cable Ø
  • TRUCK N: fixed installation 15x cable Ø

Insulation resistance:

  • TRUCK M: min. 20 MOhm x km
  • TRUCK N: min. 20 MOhm x km

Nominal voltage:

  • TRUCK N: 75 V DC

Properties

  • TRUCK M:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Polarity easy to determine by a white line on the jacket above the white conductor
  • TRUCK N:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Complies with GGVS regulations
  • Approved and tested by the TÜV technical inspectorate
  • The additional jacket means that the cable is very robust, and can be installed without a corrugated conduit
  • Installation time is shorter due to twin design
  • Polarity is easy to determine even without stripping thanks to an imprint with the type designation and on the jacket over the positive conductor. This helps prevent wrong connections
  • The special construction of the conductor enables optimal crimping
  • Easy mechanical separation of the jacket web

 

TRUCK M

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x1.5 6.8 28.8 90.0 16
2x1.5 6.8 28.8 90.0 16
272 2x1.5 6.8 28.8 90.0 16

TRUCK N

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x2.5 9.4 48.0 87.0 14
2x4 11.5 77.0 125.0 12
2x6 15.2 116.0 175.0 10
2x10 18.8 192.0 270.0 8
2x16 21.0 308.0 390.0 6
2x25 25.6 480.0 575.0 4
2x35 28.0 672.0 820.0 2
2x50 33.0 960.0 1065.0 1
2x70 36.0 1344.0 1475.0 2/0

 

 
   
   
  Copyright © 1995, ATL Technology Ltd. All rights are reserved.