Standards
• CW 1293
• IEC 60189-2
• IEC 60332-1
• UL1581 VW-1 & UL1666
• IEEE 383CI.IE
Construction
Conductors
Solid annealed bare copper 0.4/0.5/0.6/0.9mm as per class 1 of BS 6360 and IEC 60228
Insulation
Colour coded PVC T154 to BS 7878 or equivalent. LSZH option can be offered upon request
Twisted Pairs
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk
Cabling Element
Twisted Pairs/Triples/Quads
Cable Core Assembly
There are two modes of construction: layer construction and unit construction. For layer construction, cables are laid up in concentric layers to form a compact and circular cable. For unit construction, the elements shall be pairs and shall be laid up as units or sub-units. Each unit shall consist of 20 pair
Core Wrapping
Cable containing more than 12 wires has a polyester tape applied over the cable core prior to sheathing
Sheath
PVC TM51 to BS 7878 or equivalent. Grey, White or Cream colours are standard. LSZH option can be offered upon request
Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
|