Standards
• RENFE E.T. 03.365.051.6
Construction
Conductors
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228
Insulation
Solid polyethylene as per ASTM D 1248/IEC 60708
Cabling Element
Four insulated conductors are twisted together to form a quad
Cable Core Assembly
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
Electrostatic Screen
Corrugated copper tape of 0.12mm is applied longitudinally with overlap
Bedding
PE or LSZH
Electrostatic Armour
Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one
Sheath
PE, PVC or LSZH
Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
|