                   Conductor: 
                  Annealed Copper Wire (Bare Single,Bare Strand or Tinned Strand) 
                   Insulation:  
                  PE(Polyethylene) or FRPE ( Flame Retardant Polyethylene ) 
                   Braid shield: 
                  Annealed Copper Wire ( Bare or Tinned Copper) 
                   Sheath: 
                  PVC ( Polyvinyl Chloride ) 
                   Structure:  
                  
                    
                      Conductor   | 
                      Insulation   | 
                      Braid Shield   | 
                      Sheath   | 
                     
                    
                      AWG   | 
                      Construction   | 
                      Diameter   | 
                      Min. 
        Thickness   | 
                      Nominal 
        Thickness   | 
                      Diameter   | 
                      Construction   | 
                      Diameter   | 
                      Min. 
        Thickness   | 
                      Nominal 
        Thickness   | 
                      Diameter   | 
                     
                    
                      26   | 
                      1 / 0.41A   | 
                      0.41 mm   | 
                      0.686 mm   | 
                      1.04 mm   | 
                      2.50 ± 0.10 mm   | 
                      16/6/0.12   | 
                      approx. 
        3.10mm   | 
                      0.331mm   | 
                      0.775mm   | 
                      4.65 ± 0.15 
 mm   | 
                     
                    
                      24   | 
                      1 / 0.51A   | 
                      0.51 mm   | 
                      1.295 mm   | 
                      3.10 ± 0.10 mm   | 
                      24/5/0.14   | 
                      approx. 
        3.80mm   | 
                      0.331mm   | 
                      1.0mm   | 
                      5.80 ± 0.15 
 mm  | 
                     
                                     A:Bare Copper       B:Tinned Copper   ATC:Top-Tinned Strand 
                    Characteristics: 
                  
                    
                      Items   | 
                      Specification   | 
                     
                    
                      Rating   | 
                      UL:60℃ 300V   | 
                     
                    
                      Dielectric Strength   | 
                      AC 2000V / min.(Between Conductor and Shield)   | 
                     
                    
                      Spark Test AC 3000V / 0.15sec.   | 
                     
                    
                      Insulation Resistance   | 
                      Min.1000MW - Km (20℃) at DC 500V   | 
                     
                    
                      Flame Test   | 
                      UL:VW-1  | 
                     
                                        |