                   Conductor: 
                  Annealed Copper Wire,(Bare Single,Tinned Single, Tinned Strand,or Top-Tinned Strand) 
                   Insulation:  
                  SR-PVC (Semi-Rigid Polyvinyl Chloride) or XLPVC (Cross-Linked Polyvinyl Chloride)  
                   Structure:  
                  
                    
                      Conductor   | 
                      Insulation   | 
                      Conductor 
                      Resistance(20℃)   | 
                     
                    
                      AWG   | 
                      Construction   | 
                      Diameter   | 
                      Min 
        Thickness   | 
                      Nominal 
        Thickness   | 
                      Diameter   | 
                     
                    
                      32   | 
                      7 / 0.08TA   | 
                      approx.0.24 mm   | 
                      0.14 mm   | 
                      0.18 mm   | 
                      0.60 ± 0.10 mm   | 
                      597.11W / Km   | 
                     
                    
                      30   | 
                      7 / 0.10TA   | 
                      approx.0.30 mm   | 
                       0.16 mm   | 
                      0.20 mm   | 
                      0.70 ± 0.10 mm   | 
                      354.33W / Km   | 
                     
                    
                      28   | 
                      7 / 0.13TA   | 
                      approx.0.39 mm   | 
                      0.205 mm   | 
                      0.80 ± 0.10 mm   | 
                      223.75W / Km   | 
                     
                    
                      26   | 
                      7 / 0.16TA   | 
                      approx.0.48 mm   | 
                      0.21 mm   | 
                      0.90 ± 0.10 mm   | 
                      139.76W / Km   | 
                     
                    
                      28   | 
                      1 / 0.32TA   | 
                      approx.0.32 mm   | 
                      0.19 mm   | 
                      0.24 mm   | 
                      0.80 ± 0.10 mm   | 
                      232.28W / Km   | 
                     
                    
                      32   | 
                      7 / 0.08ATC   | 
                      approx.0.23 mm   | 
                      0.12 mm   | 
                      0.155 mm   | 
                      0.55 ± 0.10 mm   | 
                      578W / Km   | 
                     
                    
                      30   | 
                      7 / 0.10ATC   | 
                      approx.0.29 mm   | 
                      0.14 mm   | 
                      0.175 mm   | 
                      0.65 ± 0.10 mm   | 
                      359.50W / Km   | 
                     
                    
                      28   | 
                      7 / 0.13ATC   | 
                      approx.0.38 mm   | 
                      0.14 mm   | 
                      0.18 mm   | 
                      0.75 ± 0.10 mm   | 
                      229.40W / Km  | 
                     
                                     Note:TA:Tinned Copper , ATC:Top – Tinned Strand 
                    Characteristics: 
                  
                    
                      Items   | 
                      Specification   | 
                     
                    
                      Rating   | 
                      UL:80℃ 30V   | 
                     
                    
                      Dielectric Strength   | 
                      AC 1500V / min.   | 
                     
                    
                      Insulation Resistance   | 
                      Min. 5MW - Km (20℃) at DC 500V   | 
                     
                    
                      Flame Test   | 
                      UL: VW-1   | 
                     
                    
                      Elongation of Insulation   | 
                      Min.100 ﹪   | 
                     
                    
                      Tensile Strength of Insulation   | 
                      Min.1.05Kg / mm2   | 
                     
                    
                      Residual of Elongation after Aging   | 
                       Min. 65 ﹪of original (113℃,168H)   | 
                     
                    
                      Residual of Tensile Strength after Aging   | 
                       Min. 70 ﹪of original (113℃,168H)   | 
                     
                                        |