                | RG174 / U ( 1354 # 26 ) Coaxial Cable | 
                 
              
                |   | 
                  | 
                  | 
               
              
                 Conductor: 
                  Annealed Copper Wire (Tinned annealed Cable) 
                   Insulation:  
                  PVC (Semi-Rigid PolyvinylChloride) 
                   Structure: 
                  
                    
                      Conductor   | 
                      Insulation   | 
                      Conductor 
                      Resistance(20℃)   | 
                     
                    
                      AWG   | 
                      Construction   | 
                      Diameter   | 
                      Min 
        Thickness   | 
                      Nominal 
        Thickness   | 
                      Diameter   | 
                     
                    
                      32   | 
                      7 / 0.08TA   | 
                      approx.0.24 mm   | 
                      0.068 mm   | 
                      0.085 mm   | 
                      0.41 ± 0.02 mm   | 
                      597.11W / Km   | 
                     
                    
                      30   | 
                      7 / 0.10TA   | 
                      approx.0.30 mm   | 
                      0.08 mm   | 
                      0.10 mm   | 
                      0.50 ± 0.02 mm   | 
                      354.33W / Km   | 
                     
                    
                      28   | 
                      7 / 0.13TA   | 
                      approx.0.39 mm   | 
                      0.07 mm   | 
                      0.11 mm   | 
                      0.60 ± 0.02 mm   | 
                      223.75W / Km   | 
                     
                    
                      28   | 
                      22 / 0.07TA   | 
                      approx.0.38 mm   | 
                      0.051 mm   | 
                      0.11 mm   | 
                      0.60 ± 0.02 mm   | 
                      225W / Km   | 
                     
                    
                      28   | 
                      44 / 0.05TA   | 
                      approx.0.38 mm   | 
                      0.12 mm   | 
                      0.16 mm   | 
                      0.70 ± 0.02 mm   | 
                      225W / Km   | 
                     
                    
                      26   | 
                      7 / 0.16 TA   | 
                      approx.0.48 mm   | 
                      0.051 mm   | 
                      0.11 mm   | 
                      0.70 ± 0.02 mm   | 
                      139.76W / Km  | 
                     
                                       Characteristics: 
                  
                    
                      Items   | 
                      Specification   | 
                     
                    
                      Rating   | 
                      UL:80℃ 30V   | 
                     
                    
                      Dielectric Strength   | 
                      AC 1500V / min.   | 
                     
                    
                      Insulation Resistance   | 
                      Min. 5MW - Km (20℃) at DC 500V   | 
                     
                    
                      Flame Test   | 
                      UL: VW-1   | 
                     
                    
                      Elongation of Insulation   | 
                      Min.100 ﹪   | 
                     
                    
                      Tensile Strength of Insulation   | 
                      Min.1.05Kg / mm2   | 
                     
                    
                      Residual of Elongation after Aging   | 
                       Min. 65 ﹪of original (113℃,168H)   | 
                     
                    
                      Residual of Tensile Strength after Aging   | 
                       Min. 70 ﹪of original (113℃,168H)   | 
                     
                                        | 
                 
             
			 | 
           
          |