Cat. 7 Solid Cable    

Cat. 7 Solid Cable

Application Standard:

155MbpsATM 、 622MbpsATM 、 1000Base-T 、 10GBase-T

Standard :

IEC61156-5 CAT 7 and EN50288-4-1 。

Construction Matrix :

 

STP

SFTP

Conductor

22/23AWG Solid Plain Copper

22/23AWG Solid Plain Copper

Insulation

Polyethylene

Polyethylene

Screen

Individual Aluminum Screen

Individual Aluminum Screen+Copper Wire Braid

Drain Wire

7/0.2mm

NIL

Outer Sheath

PVC/LSOH

PVC/LSOH

Frequency :

1-600MHz ( Common standard ) 1-1000MHz ( Cat7E standard )

General Characteristics :

Nominal Velocity of Propagati on : 79%
Maxmium Mutual Capacitance : 5.6nF/100m
Maxmium Resistance Unbalance : 5%
Maxmium Propagation Delay Skew : 30ns/100m
Maxmium Propagation Delay : 536ns/100m@100MHz
Voltage Rating : 60Vrms
Maximum Pulling Load : 80N
Working Temperature : -20 ℃ — +60 ℃
Storage Temperature : -5 ℃ —+50 ℃
Flame Retardancy : IEC332-1 ( FRRVC&LSOH jacket )
IEC332-1&IEC332-3C(LSFROH jacket)

Cable Parameters :

Construction

Coductor Diameter /mm

Diameter over Insulation
/mm

Pairs

Screen

Overall Diameter
/mm

Outer Sheath

SFTP

0.57/0.64

1.02

4

Individual Aluminum Screen+Copper Wire Braid

8/9.1

PVC/LSOH

SFTP

0.57/0.64

1.02

4

Individual Aluminum Screen+Copper Wire Braid

8.5/9.5

LSFROH

STP

0.57/0.64

1.02

4

Individual Aluminium Screen

8/9.1

PVC/LSOH

STP

0.57/0.64

1.02

4

Individual Aluminium Screen

8.5/9.5

LSFROH

Transmission Parameters :

FREQ

(MHZ )

NEXT
(db/100m )
Minimum Value/Typical Value/Standard Value

ATTENUATION

(db/100m )

RETURN LOSS
(db)
Minimum Value/Typical Value/Standard Value

PPACR
( db/100m )
Minimum Value/Typical Value/Standard Value

1

90.0/100.0/80.0

2.0

20.0/23.0/20.0

88.0/98.0/80.0

4

90.0/100.0/80.0

3.6

23.0/26.0/23.0

86.4/96.0/76.4

10

90.0/100.0/80.0

5.7

25.0/28.0/25.0

84.3/94.0/74.3

16

90.0/100.0/80.0

7.2

25.0/28.0/25.0

83.3/92.0/72.8

20

90.0/100.0/80.0

8.1

25.0/28.0/25.0

82.5/91.0/71.9

31.25

90.0/100.0/80.0

10.1

23.6/26.0/23.6

80.0/90.0/69.9

62.5

90.0/100.0/75.5

14.5

21.5/24.0/21.5

76.0/85.0/61.0

100

90.0/100.0/72.4

18.5

20.1/23.0/20.1

72.5/75.0/53.9

200

90.0/100.0/67.9

26.8

18.0/23.0/18.0

65.0/70.0/41.1

250

95.0/90.0/66.5

30.2

17.3/23.0/17.3

50.0/58.0/36.3

300

95.0/90.0/65.3

33.3

17.3/23.0/17.3

59.0/55.0/32.0

600

80.0/90.0/60.8

48.9

17.3/20.0/17.3

32.0/50.0/11.9

FREQ

(MHZ )

PPELFEXT
( db/100m )
Minimum Value/Typical Value/Standard Value

PSNEXT
( db/100m )
Minimum Value/Typical Value/Standard Value

PSACR
( db/100m )
Minimum Value/Typical Value/Standard Value

PSELFEXT
( db/100m )
Minimum Value/Typical Value/Standard Value

1

85.0/90.0/80.0

87.0/97.0/77.0

85.0/95.0/75.0

82.0/87.0/77.0

4

85.0/90.0/80.0

87.0/97.0/77.0

83.4/93.0/73.4

82.0/87.0/77.0

10

79.0/90.0/74.0

87.0/97.0/77.0

81.3/91.0/71.3

76.0/87.0/71.0

16

74.9/90.0/69.9

87.0/97.0/77.0

80.3/89.0/69.8

71.9/87.0/66.9

20

73.0/90.0/68.0

87.0/97.0/77.0

79.5/88.0/68.9

70.0/87.0/65.0

31.25

69.1/90.0/64.1

87.0/97.0/77.0

77.0/87.0/66.9

66.1/87.0/61.1

62.5

63.1/85.0/58.1

80.0/97.0/72.5

73.0/82.0/58.0

60.1/82.0/55.1

100

59.0/80.0/54.0

87.0/97.0/69.4

69.5/72.0/50.9

56.0/77.0/51.0

200

53.0/75.0/78.0

87.0/97.0/64.9

62.0/67.0/38.1

50.0/72.0/45.0

250

51.0/70.0/46.0

92.0/87.0/63.5

47.0/55.0/33.3

48.0/67.0/43.0

300

49.5/66.0/44.5

92.0/87.0/63.3

56.0/52.0/29.0

46.5/63.0/41.5

600

43.4/60.0/38.4

77.0/87.0/57.8

29.0/47.0/8.9

40.4/57.0/35.4

Remark :

CMR/CMP flame jacket can be offered according to customer request.
** Worst Values refer to the worst values measured in all the four pairs. Typical Values refer to average values taken from all the measurements for any pairs. Standard Values refer to the values as stipulated in the TIA/EIA standard. Typical Values are those margins that may likely be achieved during a normal testing. Worst Values are the margin taken from the worst pairs, which is the lowest margin that can be guaranteed for the cable. Usually, a typical measurement will have a better values than the Worst Value

   
   
  Copyright © 1995, ATL Technology Ltd. All rights are reserved.
  E-mail:inquiry@atl-technology.net