Flame Retardant RG11 A/U Coaxial Cables 
.jpg)  
                            STANDARDS 
                              Basic design adapted to MIL-C-17 
                              FIRE PERFORMANCE 
                            
                              
                                 
                                  Flame Retardance (Single Vertical 
                                  Wire Test)**  | 
                                EN 60332-1-2; IEC 60332-1-2; BS EN    60332-1-2; VDE 
                                  0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN    50265-2-1*; DIN VDE 0482-265-2-1*  | 
                               
                              
                                Reduced Fire Propagation 
                                  (Vertically-mounted bundled wires 
                                  & cable test)**  | 
                                EN 60332-3-24 (cat. C); IEC 60332-3-24;    BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1);    CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4  | 
                               
                             
                            Note: Asterisk ** denotes that the standard  compliance is optional, depending on the oxygen index of the PVC compound and  the cable design. 
                              CABLE CONSTRUCTION  
                              Conductors: Tinned copper wire, stranded according to IEC(EN) 60228 class 2. 
                              Insulation: Low density PE. 
                              Overall Screen: Plain copper wire braid 
                              Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon  resistance, oil resistance, 
                              anti rodent and anti termite properties can be offered as option. Compliance to  fire performance 
                              standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen  index of the 
                              PVC compound and the overall cable design. LSPVC can also be provided upon  request. 
                            CONSTRUCTION PARAMETERS 
                            
                              
                                 
                                  Cable  
                                  Code  | 
                                Conductor  
                                  Diameter  | 
                                Nominal Insulation Diameter  | 
                                Nominal  
                                  Screen  
                                  No.x Diameter  | 
                                Nominal Overall Diameter  | 
                                Approx. Weight  | 
                               
                              
                                   | 
                                mm  | 
                                mm  | 
                                No. x mm  | 
                                mm  | 
                                kg/km  | 
                               
                              
                                FGD RG11 A/U  | 
                                7 x 0.40  | 
                                7.25 ± 0.18  | 
                                192 x 0.18  | 
                                10.3 ± 0.18  | 
                                150  | 
                               
                             
  
                               |