Flame Retardant RG59 Coaxial cables 
.jpg)  
STANDARDS 
  Basic design to MIL-C-17 
  FIRE PERFORMANCE 
  
     
      Flame Retardance (Single Vertical 
      Wire Test)  | 
    EN 60332-1-2; IEC 60332-1-2; BS EN    60332-1-2; VDE 
      0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN    50265-2-1*; DIN VDE 0482-265-2-1*  | 
   
  
    Reduced Fire Propagation 
      (Vertically-mounted bundled wires 
      & cable test)  | 
    EN 60332-3-24 (cat. C); IEC 60332-3-24;    BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1);    CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4  | 
   
  
    Halogen Free  | 
    IEC 60754-1; EN 50267-2-1; DIN VDE    0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*  | 
   
  
    No Corrosive Gas Emission  | 
    IEC 60754-2; EN 50267-2-2; DIN VDE    0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*  | 
   
  
    minimum Smoke Emission  | 
    IEC 61034-1&2; EN 61034 -1&2; DIN    VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS    7622-1&2*  | 
   
  
    No Toxic gases  | 
    NES 02-713; NF C 20-454  | 
   
 
Note: Asterisk * denotes superseded  standard. 
  CABLE CONSTRUCTION  
  Conductors: Copper clad steel, solid according to IEC(EN) 60228 class 1. 
  Insulation: PE compound. 
  Overall Screen: Plain copper wire braid 
  Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS  7655-6.1(Thermosetting LSZH 
  compound type SW2-SW4 as per BS 7655-2.6 can be offered.) 
CONSTRUCTION PARAMETERS 
  
     
      Cable  
      Code  | 
    Conductor  
      Diameter  | 
    Nominal Insulation Diameter  | 
    Nominal  
      Screen  
      No.x Diameter  | 
    Nominal Overall Diameter  | 
    Approx. Weight  | 
   
  
       | 
    mm  | 
    mm  | 
    No. x mm  | 
    mm  | 
    kg/km  | 
   
  
    RG59 B/U  | 
    0.58 ± 0.03  | 
    3.70 ± 0.10 m  | 
    120 x 0.15  | 
    6.20  | 
    60.3  | 
   
 
   |