Flame Retardant RG6 A/U Coaxial cables
STANDARDS
Basic design adapted to MIL-C-17
FIRE PERFORMANCE
Flame Retardance (Single Vertical
Wire Test)** |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE
0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation
(Vertically-mounted bundled wires
& cable test)** |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
CABLE CONSTRUCTION
Conductors: Bare copper copper wire, solid according to IEC(EN) 60228 class 1.
Insulation: Foamed PE compound.
Overall Screen: Aluminium foil(100%)+Aluminium braid (70%)
Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance,
anti rodent and anti termite properties can be offered as option. Compliance to fire performance
standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the
PVC compound and the overall cable design. LSPVC can also be provided upon request.
CONSTRUCTION PARAMETERS
Cable
Code |
Conductor
Diameter |
Nominal Insulation Diameter |
Nominal
Screen
No.x Diameter |
Nominal Overall Diameter |
Approx. Weight |
|
mm |
mm |
No. x mm |
mm |
kg/km |
FGD RG6 A/U |
1.02 |
4.57 ± 0.20 |
96 x 0.12 |
7.00 |
81.6 |
|